CERN Accelerating science

CMS Detector Performance Summaries

Senast inlagda poster:
2020-05-26
09:35
W and top tagging scale factors for Run 2 data /CMS Collaboration
This note presents the data-to-simulation scale factors used in the identification of hadronically decaying top quarks and W bosons using the full Run 2 dataset, recorded in the years 2016, 2017 and 2018, with the CMS detector corresponding to a total integrated luminosity of $137\;\text{fb}^{-1}$. Relevant kinematic distributions for the 2018 data taking period, corresponding to an integrated luminosity of $60\;\text{fb}^{-1}$, are also presented..
CMS-DP-2020-025; CERN-CMS-DP-2020-025.- Geneva : CERN, 2020 - 30 p. Fulltext: PDF;

Detaljerad journal - Similar records
2020-05-25
09:55
Performance of Electron and Photon reconstruction in the 2017 Legacy dataset of the CMS Experiment /CMS Collaboration
In this note Electron and Photon performance in CMS with the 2017 Legacy dataset for the LHCP Conference 2020 are presented..
CMS-DP-2020-024; CERN-CMS-DP-2020-024.- Geneva : CERN, 2020 - 19 p. Fulltext: PDF;

Detaljerad journal - Similar records
2020-05-13
10:17
CMS Tracker Alignment Parameter Errors performance results for full Run 2 Legacy reprocessing /CMS Collaboration
During the LHC Long Shutdown 2, the CMS experiment started a collaboration-wide effort to re-calibrate the data and optimize the simulation, reconstruction and analysis software in order to reprocess the data collected during LHC Run 2 with uniform software and detector calibrations (Legacy processing). This note collects performance results of the tracker detector alignment parameter errors obtained using the updated Legacy software and calibration for the data collected by CMS during the three years period 2016,2017 and 2018, and corresponding to an integrated luminosity of about 140/fb. [...]
CMS-DP-2020-023; CERN-CMS-DP-2020-023.- Geneva : CERN, 2020 - 10 p.

Detaljerad journal - Similar records
2020-05-13
10:17
Background studies in the CMS DT chambers during LHC Run 2 /CMS Collaboration
Characterising background in terms of trends vs LHC instantaneous luminosity and of spatial distributions, helps to understand its sources and to devise mitigation measures to prevent detector early ageing, especially in view of the Luminosity increase expected at High Luminosity LHC. During LHC Run2, the background in the CMS Drift Tubes (DT) was monitored by means of both online anode current measurements and offline analysis. For the offline analysis a method was developed to classify background and signal objects, where objects are either single hits or reconstructed track segments. Both rates and currents were observed to depend linearly on LHC instantaneous luminosity: the slopes of these trends were used as a measure of background, depending only on the chamber position. A Zero Bias data sample was used to measure both background and signal rates, however the same method can also be applied to derive conservative background estimates using samples muon enriched skimmed events. The observed spatial distribution of background supports the hypothesis of two different components: one coming directly from the interaction point, the other coming from outside the detector, through a so called neutron gas setting up in the cavern..
CMS-DP-2020-022; CERN-CMS-DP-2020-022.- Geneva : CERN, 2020 - 35 p.

Detaljerad journal - Similar records
2020-05-13
10:17
ECAL 2016 refined calibration and Run2 summary plots /CMS Collaboration
Many physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate, high resolution electron and photon energy measurements. Following the excellent performance achieved in Run I at center-of-mass energies of 7 and 8 TeV, the CMS electromagnetic calorimeter (ECAL) is operating at the LHC with proton-proton collisions at 13 TeV center-of-mass energy. [...]
CMS-DP-2020-021; CERN-CMS-DP-2020-021.- Geneva : CERN, 2020

Detaljerad journal - Similar records
2020-04-23
23:38
Performance of the pile up jet identification in CMS for Run 2 /CMS Collaboration
The excellent operation of the LHC during the Run 2 data taking (2015-2018) has allowed the machine to reach a peak instantaneous luminosity delivered to ATLAS and CMS as high as $2\times10^{34}~\mathrm{Hz~cm^{-2}}$, leading to a large number of proton-proton inelastic scatterings to occur during the same bunch crossing (``pile up''). For the 2017 and 2018 datasets, this results in an average pile up of 32. [...]
CMS-DP-2020-020; CERN-CMS-DP-2020-020.- Geneva : CERN, 2020 - 11 p. Fulltext: PDF;

Detaljerad journal - Similar records
2020-04-23
17:03
Jet energy scale and resolution performance with 13 TeV data collected by CMS in 2016-2018 /CMS Collaboration
We present jet energy scale and resolution performances with 13 TeV data collected by CMS in 2016-2018..
CMS-DP-2020-019; CERN-CMS-DP-2020-019.- Geneva : CERN, 2020 - 20 p. Fulltext: PDF;

Detaljerad journal - Similar records
2020-04-08
11:18
Mitigation of anomalous missing transverse momentum measurements in data collected by CMS at sqrt(s) = 13 TeV during the LHC Run 2 /CMS Collaboration
Proton-proton collision events with a signature of high missing transverse momentum are generally interpreted as containing high-momentum neutrinos, or possibly other invisible particles as expected in a variety of scenarios beyond the standard model, e.g. dark matter or Supersymmetry. [...]
CMS-DP-2020-018; CERN-CMS-DP-2020-018.- Geneva : CERN, 2020 - 16 p. Fulltext: PDF;

Detaljerad journal - Similar records
2020-04-07
13:12
Displaced Photons HLT Trigger on 2017 data at 13 TeV /CMS Collaboration
This note describes the performance of a dedicated HLT trigger path developed at CMS for signatures with delayed photons in 2017 data taking at CMS Experiment..
CMS-DP-2020-015; CERN-CMS-DP-2020-015.- Geneva : CERN, 2020 - 12 p. Fulltext: PDF;

Detaljerad journal - Similar records
2020-04-07
13:12
SUSY Mu+VBF Trigger Performance with 2017 Data /CMS Collaboration
SUSY Mu+VBF trigger performance results for 13 TeV from CMS are presented. The results are based on the 36.7 fb$^{-1}$ of data obtained in 2017 and include the efficiencies as a function of various variables reconstructed with the offline version of the CMS software. [...]
CMS-DP-2020-014; CERN-CMS-DP-2020-014.- Geneva : CERN, 2020 - 14 p. Fulltext: PDF;

Detaljerad journal - Similar records