Early 2018 High-Level Trigger rates /CMS Collaboration
This note presents early 2018 CMS High-Level Trigger (HLT) rate results. The rates consumed by each CMS physics group are reported..
CMS-DP-2018-057; CERN-CMS-DP-2018-057.- Geneva : CERN, 2018 - 7 p. Fulltext: PDF;

Notice détaillée - Notices similaires
2018-10-22
11:12
Efficiency of Si-strips sensors used in Precision Proton Spectrometer /CMS and TOTEM Collaborations
The Precision Proton Spectrometer (PPS) is a forward-proton spectrometer using near-beam detectors (Roman Pots, RPs) located symmetrically on both sides of IP5 at a distance of about 220 m. At The early stage of the project, the tracking RPs were equipped with Si-strip sensors used in the TOTEM experiment. [...]
CMS-DP-2018-056; CERN-CMS-DP-2018-056.- Geneva : CERN, 2018 - 12 p. Fulltext: PDF;

Notice détaillée - Notices similaires
2018-10-22
11:12
HLT Dimuon Invariant Mass Distributions In 2017 and 2018 /CMS Collaboration
Dimuon invariant mass distributions for events recorded in 2017 and 2018 and reconstructed in the CMS High Level Trigger system are shown in this note. Events are recorded largely unconstrained by requirements on muon kinematics otherwise imposed by CMS data acquisition and event reconstruction workflows. [...]
CMS-DP-2018-055; CERN-CMS-DP-2018-055.- Geneva : CERN, 2018 - 8 p. Fulltext: PDF;

Notice détaillée - Notices similaires
2018-09-24
09:39
Tau reconstruction with calorimeter jets at $ \sqrt{s} = 13 $ TeV /CMS Collaboration
We present the calo-tau algorithm, which is a dedicated high $ p_{T} $ (transverse momentum) tau reconstruction algorithm that primarily uses calorimeter hits instead of tracks. The performance of this algorithm is presented, along with a comparison with the standard HPS (Hadron Plus Strip) reconstruction algorithm. This study is work in progress, and is an attempt to tune the reconstruction for high $ p_{T} $ taus. [...]
CMS-DP-2018-054; CERN-CMS-DP-2018-054.- Geneva : CERN, 2018 - 9 p. Fulltext: PDF;

Notice détaillée - Notices similaires
2018-09-18
10:42
Boosted Gluon Fusion Higgs to bb Trigger Efficiency in 2018 Data /CMS Collaboration
This note presents the performance of a single jet high level trigger in proton-proton collisions recorded during early 2018. The trigger has been developed for the search of gluon fusion produced Higgs decaying to a pair of b quarks and utilizes a multivariate discriminant that determines the likelihood a jet contains two b quarks..
CMS-DP-2018-053; CERN-CMS-DP-2018-053.- Geneva : CERN, 2018 - 7 p. Fulltext: PDF;

Notice détaillée - Notices similaires
2018-09-12
10:40
Silicon Strip Tracker Performance results 2018 /CMS Collaboration
A campaign of measurements has been performed in 2018 to evaluate the performances of the CMS Silicon Strip Tracker. The hit efficiency and resolution measurements show a stability of the performances with results compatible with the one obtained in 2017. The hit inefficiency is predominantly due to highly ionizing particles occurring within the sensitive volume and inducing dead time in the detector. The probabilities of such rare events have been measured per p-p interaction during dedicated runs. [...]
CMS-DP-2018-052; CERN-CMS-DP-2018-052.- Geneva : CERN, 2018 - 21 p. Fulltext: PDF;

Notice détaillée - Notices similaires
2018-08-20
13:41
Tracking POG results for pion efficiency with the D* meson using data from 2016 and 2017 /CMS Collaboration
In this note the tracking efficiency measurement results are shown for data collected in 2016 and 2017. The charged pion relative efficiency is measured with an indirect method from the reconstruction of two decay chains $D^* \rightarrow D^0\pi \rightarrow k\pi\pi_{slow}$ and $D^* \rightarrow D^0\pi \rightarrow k3\pi\pi_{slow}$ in data and MonteCarlo. The uncertainty of this measurement will be systematic uncertainty associated to the charged hadron reconstruction in CMS..
CMS-DP-2018-050; CERN-CMS-DP-2018-050.- Geneva : CERN, 2018 - 10 p. Fulltext: PDF;

Notice détaillée - Notices similaires
2018-07-17
10:36
Performance of various triggers used in the Supersymmetry group in early 2018 data /CMS Collaboration
This note reviews the performances, in early 2018 data, of various triggers developed or used by the Supersymmetry group of the CMS collaboration..
CMS-DP-2018-049; CERN-CMS-DP-2018-049.- Geneva : CERN, 2018 - 26 p. Fulltext: PDF;

Notice détaillée - Notices similaires
2018-07-16
10:53
Performances of $E_T^{\text{miss}}$ trigger for heavy diboson searches in 2018 data /CMS Collaboration
Performances of a $E_T^{\text{miss}}$ trigger path have been studied on 2018 data collected by the CMS detector, corresponding to an integrated luminosity of $16.6 \text{ fb}^{-1}$, as a function of the offline missing transverse momentum, after the transverse momenta of the muons are removed from the computation, and as a function of the number of primary vertices reconstructed offline..
CMS-DP-2018-048; CERN-CMS-DP-2018-048.- Geneva : CERN, 2018 - 6 p. Fulltext: PDF;

Notice détaillée - Notices similaires
2018-07-12
09:41
Performance of CMS muon detectors in 2018 Collision Runs /CMS Collaboration
The performance of the CMS DT, RPC and CSC muon subdetectors was evaluated with the first collision data in 2018..
CMS-DP-2018-047; CERN-CMS-DP-2018-047.- Geneva : CERN, 2018 - 57 p. Fulltext: PDF;

Notice détaillée - Notices similaires