2019-02-13 06:57 |
Tests of Scintillator Tiles for the Technological Prototype of Highly Granular Hadron Calorimeter
/ Chadeeva, M (Moscow Phys. Eng. Inst. ; Lebedev Inst.) ; Korpachev, S (Lebedev Inst. ; Moscow Phys. Eng. Inst.) ; Rusinov, V (Moscow Phys. Eng. Inst. ; Moscow, ITEP) ; Tarkovskii, E (Moscow Phys. Eng. Inst. ; Moscow, ITEP)
A new technological prototype of the highly granular hadron calorimeter for future collider experiments is being developed by the CALICE collaboration. The proposed baseline design of active elements considers scintillator tiles with a silicon photomultiplier readout. [...]
2018 - 9 p.
- Published in : KnE Energ. Phys. 3 (2018) 363-371
Fulltext: PDF;
In : The 3rd International Conference on Particle Physics and Astrophysics, Moscow, Russia, 2 - 5 Oct 2017, pp.363-371
|
詳細記錄 - 相似記錄
|
2018-09-07 06:22 |
詳細記錄 - 相似記錄
|
2018-09-06 06:02 |
DQM4HEP : A generic data quality monitoring for high energy physics
/ Été, R (Lyon, IPN) ; Pingault, A (Gent U.) ; Mirabito, L (Lyon, IPN)
With increasingly sophisticated experiment, online Data Quality Monitoring (DQM) is of a significant importance for the detector and operation efficiency. Most experiments use their own Event Data Model (EDM) for data taking and built a dedicated monitoring system on top of it. [...]
Oct. - 6 p.
- Published in : 10.1109/NSSMIC.2016.8069668
In : IEEE Nuclear Science Symposium and Medical Imaging Conference, Strasbourg, France, 29 Oct - 6 Nov 2016, pp.8069668
|
詳細記錄 - 相似記錄
|
2018-09-06 06:02 |
Gain stabilization of SiPMs
/ Cvach, Jaroslav (Prague, Inst. Phys.) ; Eigen, Gerald (Bergen U.) ; Kvasnicka, Jiri (Prague, Inst. Phys.) ; Polak, Ivo (Prague, Inst. Phys.) ; van der Kraaij, Erik (Bergen U.) ; Zalieckas, Justas (Bergen U.)
We have designed and developed the adaptive power supply to keep the gain of SiPMs in the analog hadron calorimeter of the CALICE Linear Collider detector stable at the level of 1%. This power supply compensates automatically the bias voltage for temperature variations in the range 5 °C to 40 °C. [...]
2016 - 5 p.
- Published in : 10.1109/NSSMIC.2014.7431069
In : Conference Information and Promotion Committee (CIP) for the IEEE – Nuclear Science Symposium and Medical Imaging Conference, and Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors workshop, Seattle, WA, USA, 8 - 15 Nov 2014, pp.7431069
|
詳細記錄 - 相似記錄
|
2018-09-06 06:02 |
詳細記錄 - 相似記錄
|
2018-09-06 06:02 |
An Array of Spherically Dimpled Scintillating Cells for an Integrated Readout Layer
/ Dyshkant, Alexandre (Northern Illinois U.) ; Blazey, G (Northern Illinois U.) ; Francis, K (Northern Illinois U.) ; Hedin, D (Northern Illinois U.) ; Johnson, E (Northern Illinois U.) ; Zutsh, V (Northern Illinois U.) ; Lindenmeyer, C (Fermilab) ; Pla-Dalmau, A (Fermilab) ; Ramberg, E (Fermilab) ; Schellpfeffer, J (Fermilab)
The CALICE collaboration is developing calorimetry for particle flow algorithm (PFA) based detectors. To measure particle shower development, a finely segmented calorimeter optimized for PFA must consist of millions of channels. [...]
FERMILAB-CONF-14-206-E.-
SISSA, 2015
- Published in : PoS TIPP2014 (2015) 257
Fulltext: PDF; External links: PoS server; FERMILABCONF
In : International Conference on Technology and Instrumentation in Particle Physics 2014, Amsterdam, Netherlands, 2 - 6 Jun 2014, pp.257
|